DLE ENQ n Major Buffers Clear in Real Time
Code
10
16
+ 05
16
+ n
Domain of
function
n = 1
Function
Clears the major buffers in real time while off line.
n = 1: The major buffers are cleared.
Details
This command is valid while off line.
This command is executed at the reception.
When the real time command is invalid, this command is ignored.
Users should be aware that even if this command is valid and consistent with
DLE ENQ 1 in the image data, this command will be executed. (however, this
note is not necesary while on line)
The buffers cleared are:
• Receive buffer
• Print buffer
• Command edit mode