Seiko Instruments DPU-30 Printer User Manual


 
5-35
GS r n Status Transmit
Code
1D
16
+ 72
16
+ n
Domain of
function
0 n 255
Function
Returns the current printer status.
n = <xxxxxxx1>B : The status is returned
Details
n is valid only for the least significant bit.
Regardless of the validity of the automatic status response, this function returns
the current status.
For the status values, refer to Table 5-1 Status Response Value Table.
This command is executed at the deployment of the receive buffer so that the
execution of the command may be delayed depending on the conditions of the
receive buffer.
When a value is returned, the conditions of the host machine are not checked.