1-36 (E)
BKP-7933
1-8-2. Data Backup (Uploading)
n
For the details of the menu screen and the setting procedure in terminal mode, refer to the installation
manual for system setup of ROUTING SWITCHER SYSTEM.
For obtaining the installation manual of ROUTING SWITCHER SYSTEM, contact your local Sony Sales
Office/Service Center.
1. Install the BZR-10 software. (Refer to Section 1-8-1.)
2. Connect a personal computer to the REMOTE 3 port of the BKPF-R70 with an RS-232C cross cable
(9-pin to 9-pin).
3. Set the TERM/ISR switch S2-3 on the CPU-256 board of the BKPF-R70 to OFF (TERM).
4. Turn on the power of all the equipment on the S-BUS data link.
5. Turn on the power of the personal computer.
6. Start up the terminal software of the personal computer.
7. Use the Ctrl-x key combination.
The menu screen of the primary station is displayed.
8. Select “Z:SET UNIT DETECTABLE” and change the settings of the secondary stations required to
be backed up to enable.
(1) Move the cursor under the ID number of the BKP-7933.
(2) Press the Enter key. Question mark “?” turns on.
n
Question mark “?” means the unit is enabled. When the Enter key is pressed again, question mark “?”
disappears.
9. Use the Ctrl-e key combination. Next, use the Ctrl-x key combination.
Return to the menu screen of the primary station.
10. Quit the terminal software.
11. Insert the formatted FD in the disk drive of the personal computer.
12. Type as follows.
C:\>a:
"
A:\>*
"
Type “a” or “a1”.
n
“a” or “a1” is the command to start up the backup software.
Type “a” or “a1” according to the baud rate setting of S2-4 on the CPU-256 board of
the BKPF-R70.
a: When S2-4 is set to ON (The baud rate is 9600 bps)
a1: When S2-4 is set to OFF (The baud rate is 38400 bps)
1-8. Data Backup/Restore
SONY ROUTING SYSTEM SETUP MENU BKPF-R70 V1.02T STATION NUMBER 1
MODIFICATION COMMAND
A: DISPLAY CONTROL AREA B: SET SOURCE/DEST TYPE
C: SET DESTINATION NAME D: SET SOURCE NAME
E: SET LEVEL TABLE F: SET ACTIVE UNIT NUMBER
G: UPDATE BACKUP CONTROLLER H: SET GLOBAL PHANTOM
J: NAME STYLE(Type + Num) K: RESET TO DEFAULT TABLE
L: SET PHYSICAL ASSIGNMENT M: SET INHIBIT TABLE
N: SET DESCRIPTION NAME GROUP O: SET TIE LINES
P: CHANGE PASSWORD Q: CHANGE CROSSPOINT
R: CALL SECONDARY STATION
MAINTENANCE COMMAND
------------------ T: SET CLOCK
U: SELECT CONTROL MODE V: SELECT WARNING DISPLAY (ON)
W: SYSTEM STATUS LOG X: DISPLAY S-BUS COMMUNICATION
Y: DISPLAY TABLE DATA Z: SET UNIT DETECTABLE
Ctrl_X:QUIT SETUP MENU