StorageTek 4000 Switch User Manual


 
Port Detail View Page
3-8 8946121602
Table 3-4 gives a brief description of the fields in the Port Detail View page.
Table 3-4 Port Detail View Page Fields
Field Description
Port Number The port number.
Port Status The port state follows the GBIC type. The possible port states include:
No_Card – no card present in this switch slot
No_Module – no GBIC module in this port
No_Light – the module is not receiving light
No_Sync – the module is receiving light but is out of sync
In_Sync – the module is receiving light and is in sync
Laser_Flt – the module is signaling a laser fault (defective GBIC)
Port_Flt – the port has been marked faulty (defective GBIC, cable, or
device)
Diag_Flt – the port failed diagnostics (defective G_Port or FL_Port card or
motherboard)
Online – the port is up and running
Lock_Ref – the port locking to the reference signal
Port Type The port type (E_Port, G_Port or FL_Port).
Port Module (or
GBIC Module)
The GBIC type follows the port number. The four GBIC types include:
-- – no GBIC present
sw – shortwave GBIC
lw – longwave GBIC
cu – copper GBIC
Port World Wide
Name
The World Wide Name for this port.
Interrupts Total number of interrupts.
Unknown Number of unknown interrupts.
Lli Number of low level interface (LLI) interrupts.
Proc_rqrd Number of interrupts with processing (CPU) required.
Timed_out Number of timed out interrupts.
Rx_flushed Number of flushed transmissions.
Tx_unavail Number of interrupted transmissions.
Free_buffer Number of buffer interrupts.
Overrun Number of buffer overruns.
Suspended Number of suspended interrupts.
Parity_err Number of parity errors.