former Solar Inverter to your new one.
You can either take over the total yield of
the device, or the individual yield of each
energy unit. If you set the total yield of the
device, it will automatically be split among
the energy units 1 to 3 in equal shares.
If you change the yield of the individual
energy units separately, they will be added
up to the total yield.
To do so, select the menu item «change
settings» / «total yield». Here, you can
select the total yield, energy unit 1, energy
unit 2, or energy unit 3. To start changing
the displayed value, press the RIGHT arrow
key.
3.3 Internal Data Memory
Your Solar Inverter is equipped with an
internal data memory as a standard fea-
ture. With the enclosed software Sunways
Monitor, you can access these data. These
Solar Inverter data will give you detailed
information on the functioning method
and relevant values of your solar energy
supply at any time. The measured values
are stored in a ring buffer that automati-
cally overwrites the earliest values with
the latest ones. The following measured
values are stored in your Solar Inverter
NT 10000:
15 minutes average values (500 data
records, each with date/time):
· DC current
· DC voltage
· AC current
· AC voltage
· injected power
· insolation (optional)
· module temperature (optional)
129