Sunway NT 10000 Power Supply User Manual


 
Finding the Jumper «RS485 MATCH»
in the Solar Inverter
Please make sure the jumper «RS485
MATCH» is in the right position, considering
the communication interconnection you
have chosen. This jumper is on the under-
side of the interface circuit board.
Illustr.: Position of the jumper «RS485
MATCH»
Ad (6): Remote Link for up to 99 Solar
Inverters
If you wish to connect several Solar
Inverters to the remote monitoring system,
the individual Solar Inverters must be cross-
linked via RS485. The RS485 signal of the
first Solar Inverter in the row is transferred
into the interface transformer with the fol-
lowing allocation: «RS485 +» to «DATA+»
and «RS485 -» to «DATA-». Connect the
remote modem to the interface transfor-
mer. With the last Solar Inverter, the jum-
per «RS485 MATCH» must be closed. With
all other Solar Inverters, it has to be in the
open position.
To identify the individual Solar Inverters,
a clear RS485 has to be assigned to each of
them. See chapter «Setting the RS485
Address».
!