151
Error
Error 038
Back-up battery
empty
Display is blank,
despite sufficient
injection
Causes
The back-up battery on the
interface circuit board is
empty.
The display contrast is bad,
because the temperature is
high.
The display circuit board is
not supplied with electricity.
The PV generator is (partly)
covered with snow.
Remedies
Have the battery (button cell) exchanged
by a qualified person. The battery is on
the LCD display circuit board.
That can happen if the ambient tempera-
ture is high. As soon as the temperature
drops, the display will work properly
again. That does not affect the injection
of electricity.
Make sure the ribbon cable between
the display circuit board and the control
circuit board is not loose. For this pur-
pose, switch the Solar Inverter off, and
disconnect the AC and DC supply.
When doing so, please observe chapter
2.1 «Safety Instructions».
Clear the snow off the PV generator,
or wait until it has melted.
BP13370_NT_10000_englisch 23.11.2005 17:40 Uhr Seite 67