xCommand
xCommand FarEndControl Source Select
To be described.
Required parameters with (r):
CallId(r): <0..65534>
PresetId(r): <0..15>
Example:
xCommand FarEndControl Source Select CallId:3 PresetId:1
*r FECCSelectSourceResult (status=OK):
*r/end
OK
xCommand HttpFeedback Register
Command used to instruct the system to return XML feedback over HTTP(S) to specific URLs. What parts
of the Status and Configuration XML documents to monitor are specified by XPath expressions.
Required parameters with (r):
FeedbackSlot: <1..3>
ServerUrl(r): <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Expression: <S: 1, 256>
Example:
xCommand HttpFeedback Register FeedbackSlot:1 ServerUrl:10.47.19.41
Expression[1]:Status/Video Expression[2]:Status/Audio Expression[3]:Status/
Call Expression[4]:Status/Conference
OK
*r FeedbackRegisterResult (status=OK):
FeedbackSlot: 1
*r/end