e-STUDIO281c/351c/451c
Procedure
* The adjustment is performed by the service technician only.
(1) Enter adjustment mode [05]. Change the values for codes [1086 to 1088] and [840 to 843] to adjust the
sharpness intensity.
Color mode Original mode [05] code Value recommended
Acceptable
value range
Default
Text/Photo 05-840
Text 05-841
Black
Photo 05-842
Text 05-1086
Printed image 05-1087
Full color
Photo 05-1088
Gray scale --- 05-843
Set a value larger than 16. 0 to 31 0
* Setting "1" provides the softest image, while setting "31" provides the sharpest image. The default value
("0") provides an image as sharp as the one provided by setting "16."
Cautions after the completion of the adjustment
The adjustment may possibly cause moiré. In addition, when text and thin lines in a light-colored background
are scanned, the background around the text or line may be eliminated. Therefore, carefully perform the
adjustment, while checking the scanned-in image.
5. Scanning-specific Adjustments
5.5