13
Attaching Rubber Feet
A. Make sure mounting surface on the bottom of the Switch is grease and dust free.
B. Remove adhesive backing from your Rubber Feet.
C. Apply the Rubber Feet to each corner on the bottom of the Switch. These footpads
help prevent the Switch from shock/vibration.
Rack-mounted Installation
The TEG-S3000i chassis switch comes with a rack-mounted kit that can be mounted in
an EIA standard size, 19-inch Rack. The Switch can be placed in a wiring closet with
other equipment.
Perform the following steps to rack mount the switch:
A. Position one bracket to align with the holes on one side of the switch and secure it
with the smaller bracket screws. Then attach the remaining bracket to the other
side of the Switch.
B. After attached both mounting brackets, position the switch in the rack by lining up
the holes in the brackets with the appropriate holes on the rack. Secure the Switch
to the rack with a screwdriver and rack-mounting screws.
Note:
For proper ventilation, allow at least 4 inches (10 cm) of clearance on the
front and 3.4 inches (8 cm) on the back of the Switch. This is especially important
for enclosed rack installation.
Power On
Connect the power cord to the power socket on the rear panel of the Switch. The other
side of power cord connects to the power outlet. The internal power supply of the Switch
works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check the