86
12 IMAGE MEM. SELECT
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H: MEMORY
02H: LW BLK1
03H: CONTRAST
04H: FACTORY
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H: MEMORY
02H: LW BLK1
03H: NORMAL
04H: FACTORY
13 WHITE BAL. SELECT
Function
The external control equipment changes the WHITE BAL. of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00: 00H: 5400K
DATA01: 01H: 6500K
DATA02: 03H: 9300K
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00: 00H: 5400K
01H: 6500K
02H: 8500K
03H: 9300K
NOTE: Set so that at the selection of 5400K, 6500K, 8500K
of WHITE BAL. change of the following R/G/B GAIN data
cannot be accepted.
External Controls