90
20 BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H
DATA02: BALANCE Gain EAH: -22
|
FFH: -01
00H: 0
01H: +01
|
16H: +22
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H
21 ASPECT RATIO SELECT
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00 CKS
DATA00: 02H: I-WIDE
03H: LTR BOX
04H: STD 4:3
05H: ANAMPHC
ACK
7FH 60H 80H 51H 01H DATA00 CKS
DATA00: 02H: I-WIDE
03H: LTR BOX
04H: STD 4:3
05H: ANAMPHC
External Controls