Page 6.15
Operation Commands
Operation commands are used to simulate menu operations and determine the
settings of the projector, and use the following format:
op <operation> <command> [CR]
The <command> string can take one of the following formats:
<command> Description
Set = <value> Makes the setting take that value.
Get ? Asks what the current value is.
The value is returned as an ascii text string.
Increment + Adds 1 to the current value.
Decrement - Subtracts 1 from the current value.
Execute (none) Performs an action.
Example
op aspect =1 [CR] sets the aspect ratio to Theaterscope.
op aspect ? [CR] asks what is the current aspect ratio.
op bright + [CR] increments the brightness setting.
op resync [CR] commands the projector to attempt to re-synchronise to the
current input source.
The commands
Operation <command> Values Notes
aspect = ? 0 = 16:9
1 = Theaterscope
2 = 4:3
3 = 4:3 Narrow
4 = Native
memory = ? 0 = Preset A
1 = Preset B
2 = Preset C
3 = Preset D
4 = Default
save.mem = 0 = Preset A
1 = Preset B
2 = Preset C
3 = Preset D
bright = ? + - 0 - 200
contrast = ? + - 0 - 200
saturat = ? + - 0 - 200
tint = ? + - 0 - 200
sharp = ? + - 0 - 200
noise.thresh = ? + - 0 - 200
nr.simple = ? + - 0 - 200
nr.mode = ? 0 = Simple
1 = Advanced
Notes
Note: in the examples, spaces
are included for clarity, but are
not necessary in the actual
command.