Xantrex Technology XDC 10-1200 Power Supply User Manual


 
Power Supply Operation
TM-XDOP-01XN 3–41
Editing Trigger Source of a Sequence
When steps are programmed to advance step by trigger, this option allows you to
edit the source of those trigger events.
To edit the sequence’s trigger source:
Step # Do This You Will See
1 ERROR MSGS
2
6 times or .
AUTO SEQ PGM
3 Sequence 1
4
or . Use the scroll keys to
select a sequence to work with.
Sequence #
5 Edit Sequence
6
or . Use the scroll keys to
select the Trig Source option.
Trig Source
7 Trig From Man
8
or . Use the scroll keys to
select the trigger source:
Man is triggered by pressing the trigger
key.
Ext is triggered by the rear external trigger
line.
Imm is triggered by receiving an
INIT:IMM command
Bus is triggered by a GPIB GET command
or a *TRG command.
Trig from ###
9 Edit Sequence
10 The sequence’s trigger source has now been
changed. Select another sequence to work with
or escape by pressing
MENU
MENU
ENTER
ENTER
ENTER
ENTER
EXIT
TM-XDOP-01XN.book Page 41 Monday, July 17, 2006 11:19 AM