Xantrex Technology XDC 10-1200 Power Supply User Manual


 
Remote Operation
4–8 TM-XDOP-01XN
Configure Analog Control
You may configure the analog programming lines to work in either a 0 to 5V
range or a 0 to10V range. You may also select whether the voltage, current or both
are controlled with the programming lines. If you select only voltage or only
current, the other will be controlled via the front panel.
Front Panel
First, configure the analog programming lines.
Next select analog programming as the remote control interface.
Your options are
Analog V & I - voltage and current programmed via the analog interface
Analog V - voltage programmed via the analog interface; current set via front
panel
Analog I - current programmed via the analog interface; voltage set via front
panel
Step # Do This You Will See
1ERROR MSGS
2
5 times
a
REMOTE CONFIG
3
RS-232 Cfg
4
Analog Cfg
5 Input 0-5V
6
or
Select the input range.
0-5V or
0-10V
7
Setting is saved and menu is exited.
a. You can also press MENU 5 times.
MENU
ENTER
ENTER
ENTER