Xantrex Technology XDC 10-1200 Power Supply User Manual


 
Power Supply Operation
TM-XDOP-01XN 3–25
Table 3-1
Settings Affected by Recall
Feature Factory Preset Value
Voltage setpoint 0.0V
Current setpoint 0.0A
Power setpoint 103% of power rating
Triggered voltage setpoint Disabled (DEF)
Triggered current setpoint Disabled (DEF)
Triggered power setpoint Disabled (DEF)
Trigger source None
Low voltage setpoint limit 0.0V
High voltage setpoint limit 103% of voltage rating
Low current setpoint limit 0.0A
High current setpoint limit 103% of current rating
Low power setpoint 0% of power rating
High power setpoint 103% of power rating
Over voltage protection Disabled (0.0V)
Under voltage protection Disabled (0.0V) and not shutdown when tripped
Over current protection Disabled (0.0A) and not shutdown when tripped
Under current protection Disabled (0.0A) and not shutdown when tripped
Over power protection Disabled (0.0W) and not shutdown when tripped
Under power protection Disabled (0.0W) and not shutdown when tripped
Fold shutdown protection None and delay 0.5s
AC off shutdown recovery Auto recover
Over temperature
shutdown recovery
Latched
Front panel display config Show V, I & P
Knob lockout None
Aux line configuration None and active low