Xantrex Technology XDC 10-1200 Power Supply User Manual


 
About The XDC Power Supply
1–10 TM-XDOP-01XN
Table 1-6
Item Descriptions for Figure 1-5
Item Description
1 AUX A: Condition selected for auxiliary line A is TRUE.
2 Master: Power supply is selected to be the master in current share
configurations.
3 Master: Power supply is selected to be the master in current share
configurations.
4 Slave: Power supply is selected to act as a slave in current share
configurations.
5 AUTO: Power supply is in auto sequence operation.
6 Pause: Auto sequence program is paused. (Output is still on.)
Press RUN/PAUSE key to continue.
7 SEQ: Power supply is in auto sequence setup mode (if Set is also
turned on) or in auto sequence operation.
8 Trigger?: Auto sequence program is waiting for a trigger signal to
continue execution.
9 ERR: An error has occurred.
10 Set: Setting or setpoint is to be entered.
11 ADR: Power supply is being addressed (receiving data). (All
remote digital interfaces.)
12 LCL: Power supply is under local (front panel) control.
13 SRQ: Service request. GPIB only.
14 RMT: Power supply is under remote control.
15 ALARM: Power supply is operating outside the parameters the
user set by using PROT SET, or the power supply’s internal
temperature has exceeded an internally set trip point (OTP).
16 OUT OFF: Power supply output is disabled; all other circuits are
active; unit is in standby mode.
17 OVP: Power supply has exceeded an over-voltage trip point.
18 Interlock: Signals that the external shutdown line (the safety
interlock line) has been activated, disabling the supply output.
19 OTP: Power supply has exceeded an over-temperature trip point,
disabling the supply output.
20 OUT ON: Output is on.
21 Bar graphs: Graphical representation of output voltage, current,
and power.
22 CV, CC, CP: Power supply is in constant voltage mode, constant
current mode, or constant power mode.