Xerox 2750 Printer User Manual


 
2750 op#2 R3.doc 10-02 Page 2-8
Jam conditions
If a paper jam occurs in the folder, the folder attempts to process sheets within the folding system before
stopping. The diverter at the front of the bridge then flips up, closing the bridge entrance, and diverting
documents to the floor under the bridge.
A jam condition is signaled by an audible alert
(beep), and by the ERROR LED on the operator’s control
panel.
Clearing a jam
General note
When any door or other chassis cover is opened or removed, all electric motors and mechanical
components capable of causing injury are immediately disabled, whether or not a jam condition exists.
Power will be restored only
when the jam condition (if any) is cleared, and all doors/covers are replaced.
The interlock system is designed to prevent access to components
capable of causing injury. Do not try to defeat any interlock by taping or
otherwise artificially holding it closed. In the event that the service
interlock override switch is left on, the folder will emit a beep every 30
seconds.
Line voltage (115 or 230Vac) is present at exposed points on the
accordion folder base frame (back of the power entry module, and at
fuses on the power supply board). This applies whether or not the
interlock circuit is intact. Access to these danger points is prevented by a
plastic panel at the rear of the accordion folder, which must not be
removed by other than a qualified service technician.
The following sections deal with jam clearing in specific locations signaled by the display on the
operator’s control panel.
WARNING
WARNING