Xerox 721P85600 Printer User Manual


 
PREINSTALLATION
3-16 XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
Environmental/electrical requirements
Your DocuPrint 96/DocuPrint 96MX LPS has important
environmental and electrical requirements that must be
accommodated. These requirements are summarized in the table
below. For further details on electrical requirements, refer to the
following voltage charts and wiring diagrams.
Table 3-6. DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements
Environmental requirements
Operating temperature Recommended:
Minimum:
Maximum:
72° F ± 4° F/22° C ± 2° C
60° F/15.5° C
80° F/29.5° C
Humidity Recommended: 4
Minimum:
Maximum:
45% ± 10%
15%
85%
Altitude Normal:
Maximum:
Up to 6,000 feet/1830 m above sea level
9,000 feet/2743 m above sea level
Heat dissipation
System controller Operating:
Standby:
4,354 Btu per hour
2,485 Btu per hour
Peripheral cabinet (fully configured) Operating:
Standby:
3,195 Btu per hour
1,775 Btu per hour
Printer Operating:
Standby:
28,140 Btu per hour
4,454 Btu per hour
System controller U.S. and Canada, 60
Hz:
International, 50 Hz:
208/240 VAC (1 phase) or 208/220 VAC
(2 phase)
15 amp service
NEMA 6-15R or ANSI C73, 20R
KVA 1.1 (operating)
200/240 VAC +/-10%
15 amp service;
Power connector per local codes