Zebra Technologies 79695L-002 Printer User Manual


 
Configuration
Standard Control Panel Parameters
88
79695L-002 Rev. A Z Series
®
/RZ™ Series User Guide 6/6/08
ZPL only Set Delimiter Character
The delimiter character is a two-digit hex value used as a parameter place
marker in ZPL/ZPL II format instructions. See the ZPL Programming
Guide for more information.
Note • Do not use the same hex value for the control, format, and
delimiter character. The printer must see different characters to
work properly.
Default Value: 2C ,
Range: 00 to FF
To change the value shown:
1. Press SELECT to select the parameter.
2. Press MINUS (-) to move to the next digit position.
3. Press PLUS (+) to increase the value of the digit.
4. Press SELECT to accept any changes and deselect the parameter.
ZPL only Select ZPL Mode
The printer remains in the selected mode until it is changed by this
parameter or by using a ZPL/ZPL II command. The printer accepts label
formats written in either ZPL or ZPL II, eliminating the need to rewrite any
ZPL formats that already exist. See the ZPL Programming Guide for more
information on the differences between ZPL and ZPL II.
Default Value: ZPL II
Range: ZPL II, ZPL
To change the value shown:
1. Press SELECT to select the parameter.
2. Press PLUS (+) or MINUS (-) to toggle between the options.
3. Press SELECT to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 20 of 26)
Language/Parameter
Action/Explanation