Zebra Technologies R170XiTM Printer User Manual


 
Front Panel Controls
Front Panel LCD
23063L-003 Rev. 2 12/23/04 R110Xi/R170Xi User Guide 49
INIT FLASH MEM
Initialize Flash Memory
Caution • Perform this operation only when it is necessary to erase all
previously stored information from Flash memory.
1. When the LCD displays INITIALIZE CARD, press the right oval to select
YES. (If you are prompted for a password, enter your password using the
instructions in Password-Protected Parameters on page 43.)
The LCD asks
INITIALIZE FLASH.
2. Press the right oval to select YES.
The LCD asks ARE YOU SURE?.
3. Do you wish to continue?
Press the left oval to select
NO to cancel the request and return to the INIT
FLASH MEM
prompt.
Press the right oval to select
YES and begin initialization.
When formatting is complete,
INIT FLASH MEM displays.
SENSOR PROFILE
Sensor Profile
The media sensor profile may be used to troubleshoot registration problems that
may be caused when the media sensor detects preprinted areas on the media or
experiences difficulty in determining web location.
Press the right oval to start this standard calibration procedure and print a media
sensor profile.
Figure 31 shows a media sensor profile. If the sensitivity of the media and/or ribbon
sensors must be adjusted, use Calibrate Media and Ribbon Sensors on page 50 to
adjust the media and ribbon sensor sensitivity.
Figure 31 • Media Sensor Profile
Table 7 • Standard LCD Displays (Page 6 of 16)
Parameter Action/Explanation