Zebra Technologies R170XiTM Printer User Manual


 
58 R110Xi/R170Xi User Guide 23063L-003 Rev. 2 12/23/04
Front Panel Controls
Front Panel LCD
RESYNCH MODE
Resynch Mode
This parameter determines how the printer reacts if the label synchronization is lost
and the label top is not where expected.
Feed Mode—If the label top is not where expected, the printer feeds a blank
label to find the label top position.
Error Mode—If the label top is not where expected, the printer stops, enters
Pause Mode, displays the message
Error Condition Feed Label,
flashes the
ERROR light, and asserts the Service Required signal (pin 10 on
the Applicator Interface Connector).
To resynch the media to the top of the label in Error Mode, press PAUSE to exit
Pause Mode. The
ERROR light stops flashing, and the Service Required signal
is deactivated. The action of the printer is determined by the
Head Close
configuration selection (see Head Close on page 54).
Press the right or left oval to toggle between choices.
Default: FEED MODE
Selections: FEED MODE, ERROR MODE
WEB S.
These parameters are automatically set during the calibration procedure. They
should be changed only by a qualified service technician. See the Maintenance
Manual for more information on these parameters.
•Press NEXT/SAVE to scroll through these parameters.
MEDIA S.
RIBBON S.
TAKE LABEL
MARK S.
MARK MED S.
MEDIA LED
RIBBON LED
MARK LED
LCD ADJUST
Adjust LCD Contrast
This parameter allows you to adjust the contrast of your LCD if it is difficult to
read.
1. Press the left oval to move the cursor.
2. Press the right oval to toggle +/- or to increase the value of the digit.
Range: 00 to 19
FORMAT CONVERT
Select Format Conversion Factor
Selects the bitmap scaling factor. The first number is the original dots per inch (dpi)
value; the second, the dpi to which you would like to scale.
Note • Not applicable on all printers.
Press the right or left oval to display other choices.
Default: None
Selections:
None, 150 300, 150 600, 200 600, 300 600
Table 7 • Standard LCD Displays (Page 15 of 16)
Parameter Action/Explanation