Zebra Technologies R170XiTM Printer User Manual


 
82 R110Xi/R170Xi User Guide 12/23/04 23063L-003 Rev. 2
RFID Guidelines
^RB
Example 3 • This example uses the SCTIN-64 standard, which defines 64-bit structure in
the following way:
The ZPL code to write to a tag with this format would look like this:
^XA
^RB64,2,3,14,20,25
^RFW,E^FD0,3,12345,544332,22335221^FS
^XZ
These commands would put
0 in the header
3 as the filter value
12345 as the company prefix
544332 as the item reference
22335221 as the serial number
To read this EPC data and print the results on the label, you would use the following code:
^XA
^RB64,2,3,14,20,25
^FO50,50^A0N,40^FN0^FS
^FN0^RFR,E^FS
^XZ
The resulting label would look like this:
Header Filter Value
Company
Prefix Index
Item
Reference
Serial
Number
SGTIN-64 2 3 14 20 25
10
(binary value)
8
(decimal
capacity)
16,383
(decimal
capacity)
9 to 1,048,575
(decimal
capacity*)
33,554,431
(decimal
capacity)
* Capacity of Item Reference field varies with the length of the company prefix.
0.3.12345.544332.22335221