Quick start system configuration Configuring the Z-Plex
The first time you configure an IP address, you must reboot the system.
4.2.1 Logging in and out of the system
You must log into the system to manage it. Note that only one administrative user can be
logged into the Z-Plex unit at a time. The default username is user, the default password is
password.
For example, to log into the system:
login> user
login> ********
user>
To log out of the system, enter the logout command:
user> logout
Users are automatically logged out of the system under the following circumstances:
If a user is logged into the serial interface and another user logs in via telnet or another
interface.
After 10 minutes, inactive sessions are automatically logged out.
4.2.2 Setting the date
Use the DATE command to set the date on the system. For example, the following command
sets the system date to 1:30 PM, May 1, 2000:
user> SET DATE:05/01/2000 13:30:00
4.2.3 Configuring a management interface
You can configure the Z-Plex over the following interfaces:
Local
DS0
Ethernet
IP over FDL
The following sections describe how to configure each of these interfaces.