Zhone Technologies Z-PLEX-10-24-DOC-SC Network Card User Manual


 
Zhone Technologies / A-9
Alphabetical Reference Parameter reference
DSR
The Data Set Ready (DSR) option allows you to define whether the V.35 port DSR control
lead should be held on (high) or off (low).
Possible values are:
ON:
OFF (default):
Configuration group: DPCFG
Syntax:
(GET/SET) DPCFG:DSR:1:(ON/OFF)
ERRINS
Specifies that random bits are inserted while the BERT test is active for the entire T1. The only
supported value is BIT.
Configuration group: T1CFG
Syntax:
(GET/SET) T1BE:ERRINS:X:BIT
ES
The ES (errored seconds) option indicates the total number of seconds in which one or more
frames with CRC-5 errors were detected. This field is read-only.
Configuration group: PMCUR, PMTOT, PMINT, FARPMCUR,FARPMTOT, FARPMINT
Syntax:
GET (PMCUR, PMTOT, FARPMCUR, FARPMTOT):ES:x
Syntax: GET (PMINT, FARPMINT):ES:x:(0-95)
FDL
Type of FDL. Possible values are:
ANSI
ATT
OFF (default)
Notes
This setting is only required if FRAME is set to ESF.