RTLP (FXS)
The RTLP setting controls the amount of gain or loss added to the incoming signal after it is
decoded to analog. To increase the signal level, set the RTLP setting to a positive value (the
larger the number, the more gain is added). To decrease the signal level, set the RTLP setting
to a negative value (the more negative the number, the more the signal level is decreased).
For example, an incoming signal at -5.0dBm can be increased to -3.0 dBm by setting RTLP to
+2 dB. The RTLP range is -9.0dB to 3.0dB.
Configuration group: FXSCFG
Syntax:
(GET/SET) FXSCFG:RTLP:n:(-9 to 3)
RxAB (FXO)
The RxAB setting is a read-only parameter that displays the ABCD pattern for testing the
receive side of the circuit. Possible values are:
00
01
10
11
Configuration group: FXOTST
Syntax:
GET FXOTST:RXAB:n
RxAB (FXS)
The RxAB setting is a read-only parameter that displays the ABCD pattern for testing the
receive side of the circuit. Possible values are:
Possible values are:
00
01
10
11
Configuration group: FXSTST
Syntax: