ZyXEL Communications VES-1000 Switch User Manual


 
VES-1000 Series Ethernet Switch
System Maintenance 2 11-1
This chapter discusses CI Mode, Remote Management Control and Hardware Monitor SMT menus.
11.1 Command Interpreter Mode
This option allows you to enter command interpreter mode, which allows more advanced system diagnosis and
troubleshooting. Enter 8 from Menu 24 – System Maintenance. A list of valid commands can be found by typing
“help” or “?” at the command prompt. Enter “exit” to return to the SMT main menu when finished.
Figure 11-1 Valid CI Commands
See the later chapters for more detailed information on CI commands.
11.2 Time and Date Setting
Menu 24.10 - Time and Date Setting allows you to set the time manually or get the current time and date from an
external server when you turn on your VES-1000 Series switch. The real time is then displayed in the VES-1000
Series switch logs.
Select menu 24 in the main menu to open Menu 24 - System Maintenance and then enter 10 to go to Menu
24.10 — System Maintenance — Time and Date Setting to update the time and date settings of your VES-1000
Series switch as shown in the following screen.
Figure 11-2 Menu 24.10 System Maintenance - Time and Date Setting
Chapter 11
System
Maintenance 2
Valid commands are:
sys exit device ether
vdsl ip sw
test>
Menu 24.10 - System Maintenance - Time and Date Setting
Use Time Server when Bootup= None
Time Server IP Address= N/A
Current Time: 00 : 00 : 00
New Time (hh:mm:ss): 11 : 23 : 16
Current Date: 2000 - 01 - 01
New Date (yyyy-mm-dd): 2001 - 01 - 01
Time Zone= GMT+0800
Press ENTER to Confirm or ESC to Cancel:
Press Space Bar to Toggle.