3Com 4007 Switch User Manual


 
Preinstallation Guidelines
35
LED Warning
The following warning is required when you install
fiber-optic communication modules into the
Switch 4007:
WARNING:
To ensure optical safety when you install
a fiber-optic interface module, comply with the
following precaution:
Although the data communication LEDs that are used
in this product meet the regulatory requirements for
casual exposure to the eye, as with any source of
bright light, 3Com recommends that you do not look
into the light source.
LED Safety Information:
IEC 825, Class 1 LED
Device. For connection only to Class 1 LED Devices.
Preinstallation Guidelines
Use the following installation guidelines to ensure
your safety and optimal performance. Review all
guidelines before you install the Switch 4007.
Rack-Mount Installation Guidelines
Before you attempt to mount the chassis in a rack:
Select a rack that can support at least 115.65 kg
(255 lb), which is three times the weight of a fully
loaded Switch 4007 chassis, and that provides
sufficient vertical space for each chassis that you
want to install.
Make certain that the rack that you use is properly
aligned and is squared. Use a framing square to
ensure that the rack is squared.
To maintain proper cooling in the chassis and to
maintain safety compliance, make certain that
blank faceplates cover any empty slots.
Bolt the rack to the floor.
Brace the top of the rack against the wall.
CLASS 1
LED PRODUCT