3Com 4007 Switch User Manual


 
64
A
PPENDIX
A: S
PECIFICATIONS
Power
WARNING:
For use in Denmark, each 3CB9EP9
power supply must receive power from a separately
dedicated socket outlet having a 16-ampere fuse in
the installation. This product must be mounted in a
fixed installation such as a permanent rack.
WARNING:
Ved brug i Danmark, skal hver 3CB9EP9
stromforsyning modtage strom fra en separat,
dedikeret stikkontakt med en 16-ampere sikring i
installationen.
Regulatory Compliance
Total power
consumption
1431 watts, 4882 BTU/hour
Output voltage
+3.5 V @ 195 A, +5.2 V @ 46 A,
+12 V @ 6 A, +2.1 V @ 4 A
Input voltage
range
United States — 85 to 132 VAC
International — 180 to 264 VAC
Inrush current
maximum 40 A at 110 VAC
Input frequency
47 to 63 Hz
Safety
CSA 22.2 No. 950
UL1950
TUV GS mark
IEC950, CB Certificate
EN60950, with amendments
Low Voltage
Directive
For products declaring LVD
compliance on the Declaration of
Conformity
This equipment was tested and
found to conform to the Council
Directive 72/23/EEC for safety of
electrical equipment. Conformity
with this directive is based upon
compliance with the safety standard.
EMC Directive
Emissions:
EMC EN55022
EN61000-3, 2
Immunity:
EN50082-1
*EMC Directive Compliance
This equipment was tested and found to conform to the Coun-
cil Directive 72/23/EEC for safety of electrical equipment. Con-
formity with this directive is based upon compliance with the
following harmonized standards:
EN55022-Limits and Methods of Measurement of Radio Inter-
ference
EN50082-1 Electromagnetic Compatibility Generic Immunity
Standard: Residential, Commercial, and Light Industry