3Com 5000 ATM Computer Hardware User Manual


 
4-16
C
HAPTER
4: S
TATUS
M
ONITORING
AND
S
TATISTICS
BPORT_LEC Server
Circuits
The following command displays the server circuits for bridgeport-LEC 2
on an ATM Backbone SwitchModule in slot 4:
CB5000> show bport_lec 4.2 server_circuits
Bridge Port LEC Display for Module 6602M-MOD:
BP LEC Mode I/F Status General Info
--------- ------------ ------------- -------------------
04.02 ENABLED ENABLED
Configuration Direct VPI/VCI: 0/0
Control Direct VPI/VCI: 0/105
Control Distribute VPI/VCI: 0/106
Multicast Send VPI/VCI: 0/107
Multicast Forward VPI/VCI: 0/108
BPORT_LEC
LE_ARP Table
The following command displays information for an ATM Backbone
SwitchModule in slot 4:
CB5000> show bport_lec 4.2 learp_table all
Bridge Port LEC Display for Module 6602M-MOD:
BP LEC Mode I/F Status General Info
--------- ------------ ------------- -------------------
04.02 ENABLED ENABLED
MAC Address ATM Address
----------- ------------------------
08-01-20-05-05-e3 39.99.99.99.99.99.99.00.00.99.99.05.07.08.00.8f.40.a4.c0.02