3Com 5000 ATM Computer Hardware User Manual


 
Recovering from Problems
6-9
4
Use the following command to display vcc parameters:
CB5000> show atm <slot>
vcc all
Verify the following parameters settings:
SIG is 0/5
ILMI is 0/16
5
If necessary, use the following command to reset the ILMI parameter:
CB5000> set atm <slot>
ilmi pvc 0/16
ATM commands do not take effect until you reset the module. Use the
DMM RESET MODULE command to enable any ATM parameter
changes.
6
If the SIG parameter is not set to 0/5, contact your network supplier to
set the SIG parameter to 0/5 at the ATM switch.
7
Record the final settings of your ATM signalling parameters before
continuing.
Verifying LEC
Functions
Use the following procedure to verify the functions of a LEC:
1
Use the following command to display the configuration mode of the
LEC:
CB5000>
show bport_lec <slot.lec> configuration
If the configuration mode is manual, check the command display to
verify that the correct LES ATM Address is listed. The LES ATM
Address of the LEC must match the LES ATM Address of the ELAN
to which the LEC is assigned.
If the configuration mode is automatic, check the command display
to verify that the ELAN Name parameter is set to the ELAN Name
required by the ATM switch.
Contact your ATM switch service representative to determine the
correct LES ATM Address and ELAN Name setting.
2
Check the command display in step 1 to verify that the Mode
parameter for the LEC is set to Enabled.
If the Mode parameter is not set to Enabled, use the following
command to reset the Mode parameter to Enabled:
CB5000> set bport_lec <slot.lec> mode enable