Appendix C. Status Buffer Messages
74 Express XRT User Guide 61202.153L3-1
AutoSwitch YYY
Switch type YYY detected during AutoSpid determination. (YYY
can be DMS, NI-1, or AT&T)
Back to online
Express XRT went back on line.
Bad async BPS
The Bonding protocol determined that the selected asynchronous
bit rate is not supported.
Bad AT numeric
User issued an AT command with an argument that was out of
range.
Bad call type
Express XRT placed a call with an improper call type.
Bad DTE Baud
The DTE bit rate does not match a valid bit rate for the protocol
selected.
BAD_INFO_ELEM
Call control error.
Bad phone number
Express XRT attempted to call an invalid phone number.
BEAR_CAP_NOT_AVAIL
The bearer channel requested is not available.
BEARER_CAP_NOT_AUTH
Bearer capability requested is not authorized.
Bearer Mode?
Incoming call is not of a type the Express XRT can accept.
Bearer Info Cap?
Incoming call information transfer capability is not known.
BONDING (+/-XXX)
The amount of bytes or corrected delay between the B2 and B1
Bearer channels (XXX can range from -8000 to +8128).
BPS mismatch
Bonding negotiation found a bit rate mismatch.