ADTRAN ISU 128 Network Card User Manual


 
Appendix D. S-Register List
61202.029L2-1 ISU 128 User Manual 111
S42 BOND TXADD01 The number of seconds both endpoints wait for the
additional call to be connected at the end of negotiation
before deciding the BONDING call has failed. When
dialing overseas, it may be necessary to lengthen this
timer to allow for lower call routing.
Range = 0 to 255, 50 sec is default
S43 BOND TXDEQ The number of seconds both endpoints attempt to
equalize the network delay between the bearer channels
before deciding the BONDING call has failed.
Range = 0 to 255, 50 sec is default
S44 BOND TANULL The number of seconds the answering endpoint attempts
to detect the BONDING negotiation pattern from the
originating endpoint before aborting to clear channel
mode. It may be necessary to shorten this timer if the
DTE equipment connected to the ISU 128 also has
timer constraints for completing non-BONDING para-
meter negotiation.
Range = 0 to 255, 10 sec is default
S45 BOND TCID The number of seconds both endpoints attempt to
negotiate agreeable values for bearer channels and
channel capacities before deciding the BONDING
call has failed.
Range = 0 to 255, 5 sec is default
S46 V25 MODE Selects the type of V.25 bis dialing used.
0 = Asynchronous V.25
1 = HDLC V.25
2 = BISYNC V.25
3 = HDLC with flags V.25
S47 RS-366 TIME Determines the amount of time the RS-366 port will wait
for EON or inactivity to terminate a dial string before
dialing a number.
0 = Wait for EON only
10= Wait for 1 second or EON
20= Wait for 2 seconds or EON
50= Wait for 5 seconds or EON
100=Wait for 10 seconds or EON
200=Wait for 20 seconds or EON
S50 LINE MODE Selects the operating mode of the ISU 128.
0 = Dial service (switched service)
1 = Leased service (non-switched service)