Do
NOT to push
or pull
on the UV
-
lamps.
ONLY push on the back of the carriage!
11.3.3. H-Orientation Test:
This test is used to align all the heads, in reference to the Black head, both
horizontal and perpendicular.
When the engine is installed, or a print head has been exchanged, this test is
carried out by a technician.
11.3.4. Parameter Download:
After you’ve changed a parameter in the Setup file, which was marked with an
”, use this feature to validate those new values.
11.3.5. Carriage Release Test:
This feature is mainly intended for a Service engineer, it allows the release of the
Carriage motor, which is normally anchored on both side’s.
After executing, it’s possible to move the Carriage by hand from right to left.
IMPORTANT: To end this test, select “Reset Test” in the same menu, the
Carriage will move slowly back to the Home position.
11.3.6. Reset Test:
This will Reset the printer.
11.3.7. Enc. Count Test:
This test will measure the Encoder pulse.