GigaX Series L3 Managed Switch User Guide
89
Port <port number> Path Cost (1..200000000):[old port Path Cost] <new
port Path Cost>
Port <port number> EdgePort (yes/no):[old port EdgePort] <new port
EdgePort >
Port <port number> Point-to-Point (yes/no/auto):[old port Point-to-Point]
<new port Point-to-Point >
[Reload]
Restores the previous saved settings from configuration file.
CLI command : l2 stp retrieve
CLI command : l2 stp bridge retrieve
CLI command : l2 stp port retrieve
[Show Trunk]
Displays a specific trunk group settings. User can create a new trunk group by
specify a unique trunk ID, a trunk name description, the port selection criterion
(rtag), LACP mode (enabled or disable), and its trunk group member ports.
CLI command : l2 trunk show <trunk id>
[Create Trunk]
Creates a new trunk group by giving trunk ID, rtag, name, LACP mode and
port numbers. The “rtag” is the packet distribution algorithm for the trunk group.
Rtag values and corresponding meanings:
1: select port by source MAC
2: select port by destination MAC
3: select port by source and destination MAC
4: select port by source IP
5: select port by destination IP