Release 4/06 Page 41 Menu structure
5.2 Extended standard menu
The extended standard menu offers additional parameters you may use in your application. On
quitting this menu the current parameter settings are stored in memory. Further changes are
also written into memory. As long as this menu is active, no labelling is possible. By pressing
the key FEED, however, single dispense of labels is possible.
To get into the extended standard menu a password CODE has to be entered. The display
shows the first menu point. A survey of all parameters is shown below.
Display Function Data value
LPIT Label pitch AUTO/5...999 mm
CONT Label sensor contrast value AUTO/1...200
SENS Sensor status LAB or GAP
STOD Stop position of label at the dispensing edge 0.0 .... 200.0 (mm)
PRDL Product length (inhibit of further product- sensor
signals)
AUTO, 5 ... 999 mm
POS Position of label on product Up to 999.9 mm
STAD Delay time for start of applicator cycle 1 ... 9999 ms
VELO Labelling speed 0.2 ... 30 m/min
STST Check adjusted EGRA value see text
SLEW Slew speed FAST or SLOW
EGRA Electronic gear ratio adjustment 100 to 500
APT1 Dwell time for applicator 1 ... 7500 ms
APT2 Blow on time for applicator 1 ... 7500 ms
APT3 Restart delay 0 ... 5000 ms
APT4 Time constant compensation 0 ... 500 ms
ASTP End of air stream signal -20 ... 50 mm
PDT Printer dwell time OFF - 1000ms