Avery ALS 330/430 Label Maker User Manual


 
Operators Manual
ALS 330/430
Release 4/06 Page 44 Configuration menu
6.1 Handling the menu
The menu structure is shown in the following table. By means of the key PRIOR you switch to
the prior function, and with the key NEXT to the next following function in the menu.
If you press the key ENTER the current parameter value of a function is shown. The current
parameter value can be changed with the keys PRIOR FUNCTION or NEXT FUNCTION.
Values are stored by pressing the key ENTER.
Display Function of the parameter Possible data entry
DTST Test run without labels
P_S_ Product sensor detects at leading or
trailing edge of product
LEDG, TEDG
MACH Machine type 230, 720, 330, 430
MDIR Motor running direction for left or right
hand
<---- --->
MLAB Handling of missing label NONE, WARN, ERR1, ERR2,
ERR3
APSF Automatic product speed follower YES, NO
APPL Direct dispense mode, or applicators DIR, ASA, EP, RVEP
I_CH Test of inputs
O_CH Test of outputs
FACT Reset of all parameters to default values YES, NO
BAUD Baudrate of the interface NONE, 300 to 192%
PARI Parity bit NO, 0PRT, ODD, EVEN
SBIT Number of Stop bits 1 bit, 2 bit
DBIT Number of data bits 7 bit, 8 bit
RECY Recycle (simulates max labels/min) see text
DIST Distance label sensor to dispensing edge 10 ... 999 mm
LABC Number of dispensed labels see text
QUIT Return to extended standard menu