Release 4/06 Page 78 Technical specification
Details
Description
330 430
Operating environment 5 – 40°C, storage 0 – 70°C
30 - 80%, non condensing
Power consumption 300 VA
Mains voltage 100V~, 115V~, 200V~ and 230V~ 50/60Hz (6.3A for 110V else
3.15A),
+5%- 10%
10.1.1 Application specification
The labeller is designed and built for automatic applies of self-adhesive labels.
10.1.2 APSF- Sensor Specification (Optional function)
The resolution of the sensor should be selected in a way, that for 0.15mm product travel a
sensor pulse will be generated. Using a different resolution gives loose in label accuracy or
limits the highest dispensing speed.
It is possible to use one common sensor for several dispensers. In this case the sensor is
supplied from one machine or the several supply voltages switched parallel are separated with
diodes.
Supply voltage: 24 V DC
Output current: 20mA for each dispenser
Signal rise and fall time: each 1µs
Max frequency: 20 kHz
Signal ratio: 1:1 +- 12,5 %