Avery ALS 330/430 Label Maker User Manual


 
Operators Manual
ALS 330/430
Release 4/06 Page 44 Menu structure
Start delay ______________________________________________________STAD
Function: Delay time for the dispensing by means of an applicator after the product has passed
the product sensor. This value influences the position of the label on the product.
Only available if applicator is used.
Range: 1 to 9999 ms
Dispensing speed ________________________________________________VELO
Function: The labelling speed may be adjusted with the parameter VELO. Values between 0.2
and 30.0 m/min are possible. The speed has to be adjusted so that it matches the product
speed.
When an applicator is fitted to the machine, this parameter defines how fast the label will be
dispensed on to the applicator.
EGRA value check ________________________________________________ STST
Use this function to adjust the EGRA value. If the drive-roller speed is higher than that of the
conveyor then increase the EGRA value, if it is lower decrease the EGRA value so that the
conveyor speed and drive-roller speed match.
Slew speed _____________________________________________________ SLEW
Function: For some situations the labeller can run with a different, higher speed. This occurs
during compensation of a missing label on the web, positioning the label at the dispensing
edge during initialisation or after pressing the feed button if the APSF-mode is selected. The
resulting speed depends on the selection (FAST or SLOW) and the APSF-mode.
SLEW setting FAST SLOW
APSF off Max speed VELO
APSF on Max speed 12 m/min
Electronic gear ratio adjustment ___________________________________ EGRA
The parameter EGRA appears in the extended menu only after the APSF function has been
switched on.
The range of the EGRA parameter is 100 to 500, representing from 1 to 5 encoder pulses per
millimetre of conveyor movement. The full EGRA range can be used up to 30 m/min conveyor
speed.
With an applicator there is no realistic limit to the conveyor speed and at very high-speeds an
EGRA value at the lower end of the range should be used.
Dwell time _______________________________________________________ APT1
Function: Only used when an EP- applicator is necessary. It defines for how long the pneumatic
cylinder is switched on.
Available only with applicator.
Range: 1 ... 7500 ms