Release 4/06 Page 47 Menu structure
5.3 Product menu
If parameters have to be changed because of different products and labels, the product menu
can be used. The machine offers a data bank in which 14 sets of data can be stored.
If you want to switch to a particular product, select one of the product numbers by pressing
NEXT or PRIOR and confirm with ENTER .The new parameters are valid now.
After switching to a new product bank the machine assumes the label roll has been changed or
that a parameter such as STOD is different and so requires an initialisation of the label position
at the dispensing edge. This is done by pressing the FEED key after loading a new product
bank at which time the machine will move the first detected label edge to the dispense position.
Note: If the FEED key is not pressed after loading a new product bank the first
detected label edge will be moved to the dispense position at the first signal from
the product sensor!
Note: The function FACT available in the configuration menu clears all the product
banks.