Release 4/06 Page 43 Configuration menu
6. Configuration menu
Adjustments in the configuration menu are necessary during installation of the machine only. In
the configuration menu, the required optional functions can be selected. Some service
support functions in the configuration menu will be useful for the service staff.
Possible adjustments:
y
Recognition of the product at the leading or trailing edge
y
Left or right hand version of labeller
y
Machine type
y
direct dispensing or several type of applicators
y
Parameters for the interface
Possible tests:
y
In/output test
y
Test run without labelling
The function Factory initialisation resets all parameters to default values.
Calling the configuration menu
There are two ways to call the configuration menu:
y
Press the key ENTER and switching on power at the same time. The display shows
'CODE'.
y
Press the keys NEXT and PRIOR at the same time when a parameter function is displayed.
The display shows 'CODE'.
The password has to be entered by pressing the following keys:
* 1 time PRIOR FUNCTION
* 3 times NEXT FUNCTION
* 2 time ENTER
* 3 times NEXT FUNCTION
When the password is entered correctly, the display shows `DTST`. After pressing PRIOR or
NEXT the next menu, point will be shown. If a wrong password was entered, you go back to the
previous menu.