Release 4/06 Page 74 Errors and warnings
Message Meaning How to solve
set to the factory adjustment.
E__5 10V supply voltage for label
sensor low.
Short circuit in label sensor or cable.
Voltage regulator U14 is damaged.
E__6 24V Voltage low Short circuit on an output. Total load too
high i.e. max is 3A for all outputs.
Voltage regulator U1 is damaged.
Change main board.
E__7 Material initialization failed Check if the label web is threaded
through the label sensor
E__8 Error stepper motor driver The stepper motor control has detected
an error. The fault is indicated by the
LED’s on the driver.
E__9 10V supply for label sensor too
high
Voltage regulator U14 damaged
E__10 Missing label on product One or several product could not be
labelled. Distance between products too
close. Increase speed of printer.
___0 Process error (Divide overflow) Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
___1 Illegal interrupt (processing error) Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
___2 Illegal bank interrupt (processing
error)
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board
INTO Illegal interrupt INTP0 (processing
error)
Hardware failure external noise. EPROM
damaged. Turn off power and on again.
Change EPROM or main board.