Release 4/06 Page 54 Serial interface
#!SR__ The machine is set to on. The product sensor is enabled and labelling can
restart.
For a full automatic operation, the following procedure in case of an error is required:
y
#!ERRF Request error
y
#!CLRE Clear error message after fixing the error. The labeller shows „INIT“
y
#!SR__ Clear INIT message
Bit definition in error flag
Error number Error message in display Error description
0 E__0 Pressure roller open
1 E__1 End of material (4 missing labels)
2 E__2 EP-applicator error
3 E__3 checksum error configuration data
4 E__4 checksum error parameter bank
5 E__5 Error 10V low
6 E__6 Error 24V low
7 E__7 missing label on product
8 E__8 Error motor driver
Bit definition in warning flag
Warning Message in display Warning description
0 W__0 Next product start before finished
1 W__1 Product start but no material not initialised
2 W__2 EEPROM error during write
3 W__3 Interface warning
4 W__4 APSF speed too fast
5 W__5 End of material (OD-Control)
6 W__6 too many products