2-8 BE-0901E-AC-PC• BE-1201B-AC-PC
Chapter 2 Preparation of Embroidery Machine
W1656
4. Connect the control box connector SBUS2 of the first machine and the control box connector
SBUS1 of the second machine using an IF cable.
5. Attach the side cover of the control box.
6. Connect the control box connector SBUS2 of the second machine and the control box connector
SBUS1 of the third machine using an IF cable.
7. Connect the control box connector SBUS2 of the third machine and the control box connector
SBUS1 of the forth machine using an IF cable.
8. Attach a terminator included with the Machine Controller (option) to the control box connector
SBUS2 of the forth (last) machine.
• The IF cables used for connection are identical. There is no difference between the two ends of the IF
cable.
• The order of connecting four machines is arbitrary.
• The maximum number of connecting machines is four.
• A terminator should be connected to the connector SBUS2 of the lastly connected machine.
Connection to SBUS1, 2 can be interchangeable.
(Terminator)