Cabletron Systems 2E49-27R Switch User Manual


 
Appendix C: Optional Installations and Mode Switch Bank Settings
C-4 2E48-27R/2E49-27R User’s Guide
3. Use a Phillips screwdriver to remove the screws attaching the cover to
the chassis. (See Figure C-1.)
4. Remove the cover by sliding it back until it clears the front of the
chassis and then lifting it straight up and off the chassis.
To reinstall the chassis cover, perform the removal procedures in reverse.
Figure C-1 Removing the Chassis Cover
C.2.1 Setting the Mode Switches
Figure C-2 shows the location of the mode switches and the switch
settings for normal operation. These switches are set at the factory and do
not need to be changed.
Switch definitions and positions are as follows:
Switches 1 through 4 – For Cabletron Systems use only.
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing and
sets the COM port to 9600 baud for Local Management sessions.
19602-30
Chassis Cover
Chassis
Cover Screws (7)
Note: If the device was rack mounted, the four screws fastening the cover to
the front panel are removed and installed along with the rackmount brackets.
Front Panel