Cabletron Systems 2H22 Switch User Manual


 
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices
2-8 Local Management Supplement
INTERFACE # (Selectable)
Used to select the front panel interface connector (ENET 1 to ENET 4) to
which the port security settings will be applied.
2.3.1 Setting the Port Level Security
To set the security for each repeater port on a connector, proceed as
follows:
1. Use the arrow keys to highlight the INTERFACE # field.
2. Use the SPACE bar to step to the appropriate interface connector
number (ENET 1 to ENET 4).
3. Press ENTER to display the ports on the chosen interface connector.
4. Use the arrow keys to highlight the Security State field for the
interface connector.
5. Use the SPACE bar to step to the appropriate security level
(NonSecure, LockOnNext, or LockedOnAddr).
6. If the security level chosen causes the DisablePort and SendTrap
fields to display under Action On Intruder, use the arrow keys to
highlight the DisablePort field. If the security level chosen does not
cause the fields to display under Action On Intruder, proceed to
step 12.
7. To change the DisablePort setting to NoDisablePort, press the
SPACE bar to toggle the setting.
8. Use the arrow keys to highlight the SendTrap field.
9. To change the setting to NoTrap, press the SPACE bar to toggle the
setting.
10. If the security state selected is LockedOnAddr, use the arrow keys to
highlight the Address field for the port. Otherwise go to step 12.
11. Enter the MAC address, using the numerical keys. It is not necessary
to separate the numbers with dashes when entering the address.
12. To change the security on more than one port, repeat step 4 through
step 11 for each port. Then proceed to step 13 to save all settings at
once.