Cabletron Systems 2H23-50R Switch User Manual


 
Chapter 5: Local Management
5-90 2H23-50R/2H33-37R User’s Guide
Fragments (Read-only)
This field displays the number of received frames that are not the
minimum number of bytes in length or received frames that had a bad
CRC, were less than 64 bytes in length (excluding framing bits, but
including CRC bytes).
Jabbers (Read-only)
This field displays the total number of frames that were greater than 1518
bytes and a bad CRC.
Total Packets (Read-only)
This field displays the total number of frames (including bad frames,
broadcast frames, and multicast frames) received on this interface.
Total Octets (Read-only)
This field displays the total number of octets (bytes) of data, including
those in bad frames, received on this interface.
64 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were 64 bytes in length (excluding framing bits, but including FCS bytes).
65 – 127 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 65 and 127 bytes in length (excluding framing bits, but
including FCS bytes).
128 – 255 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 128 and 255 bytes in length (excluding framing bits, but
including FCS bytes).
256 – 511 Octets (Read-only)
Displays the total number of frames, including bad frames, received that
were between 256 and 511 bytes in length (excluding framing bits, but
including FCS bytes).
NOTE
It is normal for the Fragments field to increment. This is
because the RMON agent increments the field when runts are
detected (which are normal occurrences due to collisions) and
when noise hits occur.