Cabletron Systems 2H23-50R Switch User Manual


 
Chapter 3: Installation
3-6 2H23-50R/2H33-37R User’s Guide
Rack Mounting the Device
Proceed as follows to install the 2H23-50R or 2H33-37R into a 19-inch
rack:
1. Remove and discard the four cover screws (two from each side)
located along the front edges of each side of the device.
2. Locate the four 6-32 x 3/8-inch flathead cover replacement screws in
the rackmount kit. Use these screws to attach the rackmount brackets
to the device as shown in Figure 3-3.
Figure 3-3 Installing the Rackmount Brackets
3. With the mounting brackets installed, position the device between the
vertical frame members of the 19-inch rack and fasten it securely with
user supplied mounting screws as shown in Figure 3-4.
Figure 3-4 Installing the Device in a Rack
Screws (4)
Rackmount Brackets (2)
22861-04
65
CONN 1
CONN 3 CONN 4
CONN 2
2H23-50R
COM
PWR
CPU
RESET
10
100
CONN 4
CONN 3
CONN 2
CONN 1
CONN 4
CONN 3
CONN 2
CONN 1
121121
121121
Screws (4)
19-Inch Rack
65
CONN 1
CONN 3 CONN 4
CONN 2
22861-03
2H23-50R
COM
PWR
CPU
RESET
10
100
CONN 4
CONN 3
CONN 2
CONN 1
CONN 4
CONN 3
CONN 2
CONN 1
121121
121121