Security Application
Application Views 3Com PortSwitch Hubs
5-6 Management Module Guide
Security Users Table view
This view allows you to add and delete users and to modify their security
levels. The default users, Monitor, Manager, and Security, cannot be deleted.
Double-clicking an entry in this table displays the Security Enable Table
Entry view.
This table displays the following:
Status
Displays the user status. Possible values are Valid and Invalid. A value of
Invalid means the user can no longer access the device. The default users,
Monitor, Manager, and Security, can not have their status changed to Invalid.
You can update this field in the Security Users Table Entry view.
Name
Displays the user name. This is the index for the table. Empty user names are
not allowed.
Level
Displays the user access level. This access level defines the scope of
management this user can perform. The levels of security are the same as in
the Security Enable Table described on Page 5-5. You can update this field for
all users except the default users.
Password
Displays the password required for user confirmation when access is made
from the local serial port, the front panel, or through Telnet. The Password
field is only available in the Security Users Table Entry view and is a write-
only field.
Community
Displays a string identifying the user when access is through the original
community-based SNMP (RFC1157). You can update this field.
Local Party
Displays the local party identity of the user when access is through secure
SNMP. You can update this field.
Manager Party
Displays the manager party identity of the user when access is through secure
SNMP. You can update this field.
Allows you to add entries to the table.
Add Entry