Cabletron Systems DLE32-MA Switch User Manual


 
DELF3-UI
DLE28-MA, DLE38-MA, DLE29-MA and DLE39-MA User’s Guide B-3
B.3 DELF3-UI
The DELF3-UI shown in uses an SC style connector that supports single
mode fiber optic cabling. Specifications for the DELF3-UI are listed in
Table B-2 below.
Figure B-3 DELF3-UI
Table B-2 Transmitter Power
Cable Type Worst Case Budget Typical Budget
8/125 µm fiber >10.0 dB <10.0 dB
12/125 µm fiber >10.0 dB <10.0 dB
The transmitter power levels and receive sensitivity levels
listed are peak power levels after optical overshoot. A peak
power meter must be used to correctly compare the values
given above to those measured on any particular port. If power
levels are being measured with an average power meter, add 3
dB to the measurement to compare the measured values to the
values listed above.
26
25
LKG
-
10787
-
98F
DELF3-UI